Maximum flexibility for your lab
The Weco E52 provides you with all the tools you need to achieve the best results in optical craftsmanship. From different bevel types and groove, to angular drilling, the E52 is the premier answer for modern frame fashions and maximum flexibility for your lab.
The CT46 combines the best available tracing methods. One innovative feature is the very smooth manual blocking system. The TrueScan tracing mechanism ensures extremely accurate
and reproducible results. Together with GraviTech technology, all types of frames will be traced with unparalleled precision.
The stylus technology allows precise binocular tracing of frames up to a base curve 9. By tilting, the stylus tip always touches the bottom of the frame groove, delivering perfect results even on asymmetric frame groove profiles.
The CT46 can accurately reconstruct broken or defective demo lenses with minimal effort.
Weco E52 intelligently adjusts its edging cycles to the thickness of the lens and material.
New sensors and improved software maintain constant pressure on the lens, thus reducing edging time with no risk of misalignment, especially on hydrophobic lenses.
Beside the standard bevel programs, there is also a manual bevel program available which allows yo to manipulate the bevel position at any point of the lens shape after the measuring cycle is performed. This allows full operator control of the bevel prior to edging.

DIMENSIONS CT46
DIMENSIONS E52

Weco CT46 – Tracer / Blocker
| Data base | • Number of jobs: 5 000 • Number of shapes: 10 000 • Number of Frame Manufacturers / Folders: 100 |
| Mechanical Trace | • Powered by unique TrueScan Frame Tracing Technology • Low Pressure clamping • Reduced Tracing pressure • Adapted Tracing speed • Binocular Tracing in ~31s • Tilted Stylus Technology for binocular tracing up to base 9 • Easy operation through touchscreen |
| Optical Trace | • Powered by patented GraviTech in HD • Maximum «A» Dimension: 70mm • Maximum «B» Dimension: 60mm • Shape Modification • Automatic Drill Hole Detection • Easy Drill Hole Modification and Placement |
| Centering / Blocking | • Parallax Free Decentration and Blocking • High Definition Camera • Highlight and Visualize Laser engravings • 3D Pupillary Distance Correction |
Weco E52
| Standard Configuration | • Torque Management System(TMS) advanced edging cycle. • Four 90mm wheels that edge all materials including CR39, Polycarbonate, Trivex, High-Index, and Glass. • Integrated drilling functions including countersunk holes, notches, blind, and oblong holes. The drilling angle adjusts dynamically from 0-30°. • Front and backside lens curvature measurement accuracy of 50 microns. • Visual preview of lens before starting the roughing cycle. • 4 different bevel program modes including Percentage(default), Base curve, Controlled Bevel(manual), and Automatic. • Variable chuck pressure based on lens material and coatings. • Minimum edging diameters: Rimless Polish = 17mm, Grooved Polish = 18.2mm, Bevel Polish = 18.6mm, Polish with Safety Bevel = 21mm. • This needs to be positioned above edging diameters. • 4 different grooving modes including Percentage(default), Base curve, Controlled Bevel(manual), Automatic. • Front and backside safety bevel. |
| Other Features / Options | • VCA / OMA standard data protocol through RS232 or optional TCP / IP interface • Compatible with Weco equipment |
| Mineral lenses | Organic lenses | Flat polishing | V polishing | Grooving | Safety bevel | Drilling | Mini bevel | High base lenses | Partial finishing | Smart Design | Step bevel | Noiseless motor | TMS | Anti-slippage cycle | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Briot Perception 3 Groove | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | |||||||
| Briot Perception 3 | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||||
| Briot Emotion 3 | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||||
| Briot Evolution | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||||
| Briot Attitude 3 (ALL) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||
| Briot Attitude 3 (PLA) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||
| Briot Couture (ALL) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||
| Briot Couture (PLA) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||
| Weco E13 Groove | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | |||||||
| Weco E13 | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||||
| Weco E33 | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||||
| Weco E52 | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | |||||
| Weco E62 (All) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||
| Weco E62 (Pla) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||||
| Weco E7 (ALL) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||
| Weco E7 (PLA) | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
[Case Study MW 50D] Screening for Cataract
Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery
Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol
SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot
Dr. Gray Sass, OD Wildwood Eyecare
[Case Study MW 50D] Screening for Cataract
Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery
Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol
SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot
Dr. Gray Sass, OD Wildwood Eyecare
Briot is my choice for lab equipment,
Jonathan Kuckler, Vice President and Managing Optician North Colorado Optical of Greeley Inc.
I’m an old school optician
Trish Hammons, A.B.O.C. Custom Optical

My office has had a Briot edger for over 10 years
Dr. Albert Morier Consumer Optical

”Implementing the Briot® Attitude 2 has been effortless. It saves me time so I don’t need to spend extra hours in the office.“
Dr. Douglas King Owner, Family Eye Care Optometry Center

Dr. Paul Karpecki Kentucky Eye Institute
Dr. Paul Karpecki Kentucky Eye Institute

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.
Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.
“The VX65 refraction system is adaptable, quick to learn and easy to administer.”
Clark DeShon, OD, FAAO Practice Owner, Olney EyeCare

“I can safely and efficiently practice while also giving the patient confidence they are receiving top notch and modern care.”
Jordan Jones, O.D. Director of Eyecare, Wear Eyewear