Weco E33

The best finishing results with optimal control

Visionix introduces the next-generation all-in-one edging systems: the Weco E33 delivering exceptional results for finishing workshops, combining reliability and accessibility.

Discover the main benefits of Weco E33

New controled edging cycle

The new controlled edging cycle introduces an advanced anti-slippage feature that keeps the ophthalmic lens securely in place during the edging process, preventing misalignment or damage. When used with Visionix’s recommended double-sided pads, it ensures superior stability and precision. The adjustable edging wheel speed, along with these pads, enables safe handling of high-value lenses while delivering flawless finishes with improved control.

Gravitech technology

With Gravitech-powered tracing, you can effortlessly scan a demo lens in just a few seconds, offering accuracy that surpasses that of a mechanical tracer.

Drill mounts made effortless

Drill mount work has never been simpler. With Gravitech®, there’s no need to waste time manually programming drill mounts. Simply scan the demo lens, and the drill mount holes are immediately identified with minimal adjustments required.

No demo lens? No worries

The Weco E33 is fitted with a mechanical tracer, allowing you to work even when a demo lens is not available.

Clearly view lens markings and engravings

Equipped with a high-definition optical camera, the Weco E33 ensures that laser engravings on progressive lenses are displayed clearly and effortlessly.

10° Tilted Drilling and Grooving

Expand your eyewear offerings to include rimless and semi-rimless styles without the high costs. The Weco E33 allows you to eliminate expensive lab fees.

Manufacturer's warranty

All parts are covered for up to 2 years, with fast response support to ensure maximum uptime and an extended machine lifespan.

Technical Specifications

Dimensions

Dimensions

  • DEPTH: 23.6 in (600 mm)
  • HEIGHT: 17.9 in (455 mm)
  • WEIGHT: 151lb (68,5 Kg)
  • VOLTAGE: 230 V-50 Hz, 115 V-60 Hz

Complies with safety directives:
EN 61010-1, Di 2006/42/EC, Di 2014/35/UE, Di 2011/65/UE, Di 2012/19/UE
Complies with EMC directives: Di 2014/30/EC, EN 61000-3-3 (EN 55016-2-3 “Classe B”), EN 61000-3-2, EN 61000-6-2
UL standards for 120 V version: UL/CSA 61010-1


Features

Tracing

  • Automatic 3D-Tracing
  • Monocular or Binocular Tracing Consecutively
  • Smooth manual frame clamping
  • Optical Tracing of all kinds of demo lenses with patented GraviTech® Technology
  • Automatic Drill Hole Detection
  • Shape Creator for freedom in designing shapes

Shape- Administration

  • Job-Memory: 2,000 Jobs (incl. Centring and Edging Parameters)
  • Shape-Memory: 10,000 Shapes with easy USB Database Import / Export
  • Shape Modification: A / B / ½B / Circumference / Shape-Axis

Centering

  • Single Vision, Bifocal, Trifocal, Progressive (Markings or Engravings) Parallax-free digital manual centering
  • Manual blocking

Edging

  • Processing of Glass, CR39, High Index, Polycarbonate and Trivex®
  • Both sided measuring of the lens with one touch probe
  • Different types of bevels, including new mini bevel
  • Polishing of Flat and V-Bevel
  • The new edging mode features an advanced anti-slippage cycle

Grooving / Drilling

  • Grooving with a fixed angle of 10° incl. different programs
  • Variable Groove width and depth
  • Chamfering: Front in one step / Back in 3 steps
  • Fixed 10° drilling angle for holes, slots and notches

Communication

  • OMA V3.10
  • Remote Tracing Capability

Model Comparison Feature
           
Briot Perception 3 Groove✔️✔️✔️✔️✔️✔️✔️✔️
Briot Perception 3✔️✔️✔️✔️✔️✔️✔️✔️✔️
Briot Emotion 3✔️✔️✔️✔️✔️✔️✔️✔️✔️
Briot Evolution✔️✔️✔️✔️✔️✔️✔️✔️✔️
Briot Attitude 3 (ALL)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Briot Attitude 3 (PLA)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Briot Couture (ALL)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Briot Couture (PLA)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Weco E13 Groove✔️✔️✔️✔️✔️✔️✔️✔️
Weco E13✔️✔️✔️✔️✔️✔️✔️✔️✔️
Weco E33✔️✔️✔️✔️✔️✔️✔️✔️✔️
Weco E52✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Weco E62 (All)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Weco E62 (Pla)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Weco E7 (ALL)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️
Weco E7 (PLA)✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️✔️

Testimonials

[Case Study MW 50D] Screening for Cataract

Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery

Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol

SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot

Download complete testimonial

Dr. Gray Sass, OD Wildwood Eyecare

Testimonials

[Case Study MW 50D] Screening for Cataract

Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery

Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol

SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot

Download complete testimonial

Dr. Gray Sass, OD Wildwood Eyecare

Briot is my choice for lab equipment,

Download complete testimonial

Jonathan Kuckler, Vice President and Managing Optician North Colorado Optical of Greeley Inc.

I’m an old school optician

Download complete testimonial

Trish Hammons, A.B.O.C. Custom Optical

My office has had a Briot edger for over 10 years

Download complete testimonial

Dr. Albert Morier Consumer Optical

”Implementing the Briot® Attitude 2 has been effortless. It saves me time so I don’t need to spend extra hours in the office.“

Download complete testimonial

Dr. Douglas King Owner, Family Eye Care Optometry Center

Dr. Paul Karpecki Kentucky Eye Institute

Download complete testimonial

Dr. Paul Karpecki Kentucky Eye Institute

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.

Download complete testimonial

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.

“The VX65 refraction system is adaptable, quick to learn and easy to administer.”

Download complete testimonial

Clark DeShon, OD, FAAO Practice Owner, Olney EyeCare

“I can safely and efficiently practice while also giving the patient confidence they are receiving top notch and modern care.”

Download complete testimonial

Jordan Jones, O.D. Director of Eyecare, Wear Eyewear

Peter Remm -Kühl Optik

Mr Ganivet

Mr Notarianni

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Chistophe Baudoin

Dr. Emily Enright

Dr. Jeff Gerson

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Kambiz Silani

Dr. Kambiz Silani

Need more information?

Our teams are at your disposal to advise you

Meet Iris your Visionix assistant  

Need help?


Get instant answers, explore our solutions, and find the right product in seconds.

  • Available 24/7
  • Multilingual
  • Connects you to our experts when needed

 

Start chatting with Iris now and discover a smarter way to navigate Visionix!