Multimodal platform, diagnostic device for the anterior chamber, screening and analysis of the vision
The screening services provided by the VX 120+ give you the opportunity to alert your patients of pathologies like glaucoma, cataracts, keratoconus, as well as correcting vision defects including those affecting night vision, and in so doing complete the panel of services that you offer as an optician / optometrist. Earning client loyalty through competent care and good relationships becomes easier. By giving the client more time, with more information about their visual health, they will naturally recognize your long-term added value.
Feature | Value |
---|---|
AR-K | • |
Occular Aberro. | • |
Retro | • |
Corneal Topograph | • |
Non Contact Tonometer | • |
Feature | Value |
---|---|
Pachymetry | • |
Full Eye Tracking | • |
Back surface of the cornea | |
Remote Acces | • |
Offline/Webservice | • |
Colour camera |
Feature | Value |
---|---|
NBUT | |
Efron classification | |
Tear meniscus value |
Feature | Value |
---|---|
Alignment | XYZ automatic |
Display | 10.1” (1 024 x 600) TFT multi-touch screen |
Observation area | ø 14 mm |
Medical device directive | EC MDD 93/42/EC modified by directive 2007/47/EC |
Output | RS232 / USB / VGA / LAN |
Feature | Value |
---|---|
Spherical power range | -20D to +20D |
Cylinder power range | 0D to + 8D |
Axis | 0 to 180° |
Measuring area | Min. ø 2 mm – Max. 7 mm (3 zones) |
Number of measuring points | 1,300 points |
Acquisition time | 0.2 sec |
Method | Shack-Hartmann |
Feature | Value |
---|---|
Method | Continuous horizontal scan with the Scheimpflug camera |
Pachymeter measuring range | 150-1300 μm |
Pachymeter resolution | +/- 10 microns |
IC angle measuring range | 0°-60° |
IC resolution | 0.1° |
Pupil illumination | Blue light 455 nm |
Feature | Value |
---|---|
Number of rings | 24 |
Number of measuring points | 6.144 |
Number of points analyzed | More than 100,000 |
Diameter of covered corneal area at 43D | From 0.75 mm to more than 10 mm |
Measurement range | From 37.5 D to 56 D |
Repeatability | 0.02 D |
Method | Placido rings |
Feature | Value |
---|---|
Measurement range | 7 mmHg to 44 mmHg |
VX 110 | VX 120+ | VX 120+ Dry Eye | VX 130+ | VX 650 | |
---|---|---|---|---|---|
AR-K based WF. | |||||
AR-K | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Occular Aberro. | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Retro | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Corneal Topograph | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Non Contact Tonometer | ✔️ | ✔️ | ✔️ | ✔️ | |
Scheimpflug Camera | ✔️ | ✔️ | ✔️ | ✔️ | |
Pachymetry | ✔️ | ✔️ | ✔️ | ✔️ | |
Full Eye Tracking | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Back surface of the cornea | ✔️ | ✔️ | |||
Remote Access | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Colour camera | ✔️ | ✔️ | |||
Dry eye | ✔️ | ✔️ | |||
NBUT | ✔️ | ✔️ | |||
Efron classification | ✔️ | ✔️ | |||
Tear meniscus value | ✔️ | ✔️ | |||
Fundus Camera | ✔️ |