Client-side use vx 90
use vx 90
Ticket vx 90
Tilting screen vx 90
screen vx 90
screen inside vx 90

Visionix VX 90

ARK with auto fog system

The VX 90 is an ophthalmic diagnostic device with refraction and keratometry functionalities as well as accurate of cataracts. A moving fixation target with auto fogging allows the patient to fully desaccommodate in order to get the patient refraction in any conditions.

Discover the main benefits of Visionix VX 90

Refraction

Measure the refraction of the eye by indicating sphere, cylinder and axis

Keratometry

Measure the central and peripheral keratometry

Backlighting

Be aware of the presence of cataracts by using backlighting for internal opacity detection

Technical Specifications

Dimensions

  • WIDTH: 480 mm (18.9 in)
  • DEPTH: 288 mm (11.3 in)
  • HEIGHT: 500 mm (19.7 in)
  • WEIGHT: 14 kg (30 lbs.)

Features

General

  • Target Fixation: Auto fog system
  • Measurement data display: 7” TFT colour LCD with touch screen (800×480)
  • PD Measurement: 85 mm measuring range max, 1 mm display unit
  • Measurement data recording: Built in thermal printer
  • External output terminal: RS232/WIFI
  • Power source, power consumption: 110V-240V AC, 50/60 Hz, 50 VA
  • Standards: Compliance with Medical Device Directive 93/42/EC

MEASUREMENT specification

  • Power Range: -20 D to +20 D
  • Power Accuracy: +/- 0.25 D
  • Astigmatism range: 0 to 10D
  • Astigmatism accuracy: 0.25 D
  • Axis range: 0° to 180°
  • Axis step: 1°
  • Axis accuracy: +/- 5°
  • Pupil diameter measured: 2,5 mm minimum

keratometry specifications

  • Corneal radius range: 5 mm to 10 mm
  • Corneal refractory power: 33D to 67D (n=1.3375)
  • Power repeatability: 0.03 mm
  • Corneal astigmatic power: 0 to 12 D
  • Astigmatism accuracy: 0.02D
  • Axis range: 0° to 180°
  • Axis step: 1°
  • Axis accuracy: +/- 5°
  • Measurement diameter: 2 mm to 12 mm
  • Peripheral keratometry: Nasal, temporal, up, down

Testimonials

[Case Study MW 50D] Screening for Cataract

Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery

Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol

SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot

Download complete testimonial

Dr. Gray Sass, OD Wildwood Eyecare

Testimonials

[Case Study MW 50D] Screening for Cataract

Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery

Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol

SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot

Download complete testimonial

Dr. Gray Sass, OD Wildwood Eyecare

Briot is my choice for lab equipment,

Download complete testimonial

Jonathan Kuckler, Vice President and Managing Optician North Colorado Optical of Greeley Inc.

I’m an old school optician

Download complete testimonial

Trish Hammons, A.B.O.C. Custom Optical

My office has had a Briot edger for over 10 years

Download complete testimonial

Dr. Albert Morier Consumer Optical

”Implementing the Briot® Attitude 2 has been effortless. It saves me time so I don’t need to spend extra hours in the office.“

Download complete testimonial

Dr. Douglas King Owner, Family Eye Care Optometry Center

Dr. Paul Karpecki Kentucky Eye Institute

Download complete testimonial

Dr. Paul Karpecki Kentucky Eye Institute

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.

Download complete testimonial

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.

“The VX65 refraction system is adaptable, quick to learn and easy to administer.”

Download complete testimonial

Clark DeShon, OD, FAAO Practice Owner, Olney EyeCare

“I can safely and efficiently practice while also giving the patient confidence they are receiving top notch and modern care.”

Download complete testimonial

Jordan Jones, O.D. Director of Eyecare, Wear Eyewear

Peter Remm -Kühl Optik

Mr Ganivet

Mr Notarianni

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Chistophe Baudoin

Dr. Emily Enright

Dr. Jeff Gerson

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Kambiz Silani

Dr. Kambiz Silani

Need more information?

Our teams are at your disposal to advise you