



Visionix VX 75 Examination Slit Lamp
Excellent optics and brilliant image distinguish the Visionix VX 75 Slit Lamp from competing models. Reliable optics and light technology assure superior imaging quality. Experience high contrast and brilliant pictures with Multi-coated AR optical lenses.
The system consists of a digital video camera and software for processing data.
Eyepix 3 allows you to document and visualize your process and / or results to dynamically display.
The screen allows you to follow in real time your exam and so reassure your patient.

| Feature | Value |
|---|---|
| Magnifications | 3x/5x |
| Convergent version | • |
| Height adjustment: | • |
| Slit width | 0 – 14 mm Continually |
| Slit length | 1,8 – 13mm Continually |
| Slit apertures | 14; 9; 5,5; 0,3mm |
| Tyndall point | Ø 0,3mm |
| Slit rotation | ± 90° Continually on TABO scheme |
| Working distance | 68mm |
| Average viewing height | 375mm |
| Light | LED |
| Max light intensity | 350 000 Lux |
| Longitudinal (In/Out) | 113mm |
| Lateral (Left/Right) | 107 mm |
| Vertical (Up/Down) | 30 mm |
| Chin-rest height | 76 ±1mm |
| Stereo angle | 6° |
| Eyepiece | 12,5x |
| Total magnification/field of view (in mm) for 3 magnifications | 8x /30 ; 14x /16 ; 24x / 9 |
| Total magnification/field of view (in mm) for 5 magnifications | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 |
| Pupillary adjustement | 48,5 – 80mm |
| Diopter ajustment | +/- 6D |
| Blue (fluorescence) | • |
| Green (red-free) | • |
| Grey (anti heat) | • |
| Yellow | • |
| Power supply | 8475-8001-00 |
| Power supply for the slit lamp | ~12V AC |
| Power supply for the fixation point | 12V |
| Input voltage | 100V/120V/230V/240V AC; 60/50Hz |
| Fusible | 100-120V CA — 1A 230-240V CA — 0,5A |
| Width | 296mm |
| Depth | 313mm |
| Height | 433±15mm |
| Weight | Lamp: 7,4Kg Digital lamp: 8,1Kg |
| MDD, CE | • |
| Safety class | I |
| Parts applied | Type B |
| Tonometer | 8475-8000-00 |
| Tonometer support plate | 8475-8002-00 |
| Compatibility with EyePix3 | • |
| VX 70 | VX 75 | VX 80 | VX 85 | |
|---|---|---|---|---|
| Magnifications | 2x/3x/5x | 3x/5x | 3x/5x | 3x/5x |
| Convergent version | ✔️ | ✔️ | ✔️ | ✔️ |
| Height adjustment: | ✔️ | ✔️ | ✔️ | ✔️ |
| Height adjustment motorized version: | ✔️ | |||
| Slit width | 0 - 14 mm Continually | 0 - 14 mm Continually | 0 - 14 mm Continually | 0 - 12mm Continually |
| Slit length | 0 - 14 mm Continually | 1,8 - 13mm Continually | 1 - 12mm Continually | 1,5 - 11mm Continually |
| Slit apertures | 14; 10; 6; 4; 3; 1; 0,2mm | 14; 9; 5,5; 0,3mm | 12; 9; 5; 3; 1; 0,2mm | 12; 8; 5; 0,2mm |
| Tyndall point | Ø 0,2mm | Ø 0,3mm | Ø 0,2mm | Ø 0,2mm |
| Slit rotation | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme |
| Working distance | 100mm | 68mm | 88mm | 68 mm |
| Average viewing height | 375mm | 375mm | 375mm | 375mm |
| Light | LED | LED | LED | LED |
| Max light intensity | 300 000 Lux | 350 000 Lux | 350 000 Lux | 350 000 Lux |
| Longitudinal (In/Out) | 99mm | 113mm | 113 mm | 113 mm |
| Lateral (Left/Right) | 118mm | 107 mm | 107 mm | 100mm |
| Vertical (Up/Down) | 30mm | 30 mm | 30 mm | 30mm |
| Chin-rest height | 76mm | 76 ±1mm | 66 ±1mm | 70mm |
| Stereo angle | 6° | 6° | 6° | 6° |
| Eyepiece | 10x | 12,5x | 12,5x | 12,5x |
| Total magnification/field of view (in mm) for 2 magnifications | 10x/27; 16x/16 | |||
| Total magnification/field of view (in mm) for 3 magnifications | 10x/27; 16x/16; 25x/11 | 8x /30 ; 14x /16 ; 24x / 9 | 8x /30 ; 14x /16 ; 24x / 9 | NA |
| Total magnification/field of view (in mm) for 5 magnifications | 6x/43; 10x/27; 16x/16; 24x/11; 40x/7 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 |
| Pupillary adjustement | 52 - 90mm (2 magnifications) 55 - 75mm (3 or 5 magnifications) | 48,5 - 80mm | 48,5 - 80mm | 48,5 - 80mm |
| Diopter ajustment | +/- 6D | +/- 6D | +/- 6D | +/- 6D |
| Blue (fluorescence) | ✔️ | ✔️ | ✔️ | ✔️ |
| Green (red-free) | ✔️ | ✔️ | ✔️ | ✔️ |
| Grey (anti heat) | ✔️ | ✔️ | ✔️ | ✔️ |
| Yellow | ✔️ | ✔️ | ✔️ | |
| Power supply | Provided | 8475-8001-00 | 8475-8001-00 | 8485-8001-00 |
| Power supply for the slit lamp | 3,4V, 700mA | ~12V AC | ~12V CA; | 12V AC |
| Power supply for the fixation point | 5v | 12V | 12V | 12V |
| Input voltage | 110V / 220V AC; 60/50Hz | 100V/120V/230V/240V AC; 60/50Hz | 110V / 220V AC; 60/50Hz | 110V / 220V AC; 60/50Hz |
| Fusible | NA | 100-120V CA -- 1A 230-240V CA -- 0,5A | 100-120V CA -- 1A 230-240V CA -- 0,5A | 1,2A |
| Width | 380mm | 296mm | 299mm | 240mm |
| Depth | 530mm | 313mm | 313mm | 300mm |
| Height | 780mm | 433±15mm | 644±15mm | 440mm |
| Weight | Packed: 26Kg (2 magnifications), 28Kg (3 or 5 magnifications) | Lamp: 7,4Kg Digital lamp: 8,1Kg | Lamp: 8,7Kg Digital lamp: 9,4Kg | 12,0Kg Instrument (excluding accessories; Headrest: 1,5Kg) |
| CE : MDR - (EU) 2017/745 | ✔️ | ✔️ | ✔️ | ✔️ |
| Safety class | I | I | I | I |
| Parts applied | Type B | Type B | Type B | Type B |
| Tonometer | 8480-5010-00 | 8475-8000-00 | 8480-8000-00 | 8475-8000-00 |
| Tonometer support plate | Provided with the tonometer | 8475-8002-00 | 8480-8003-00 | 8475-8002-00 |
| Compatibility with EyePix3 | ✔️ | ✔️ | ✔️ |
[Case Study MW 50D] Screening for Cataract
Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery
Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol
SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot
Dr. Gray Sass, OD Wildwood Eyecare
[Case Study MW 50D] Screening for Cataract
Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery
Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol
SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot
Dr. Gray Sass, OD Wildwood Eyecare
Briot is my choice for lab equipment,
Jonathan Kuckler, Vice President and Managing Optician North Colorado Optical of Greeley Inc.
I’m an old school optician
Trish Hammons, A.B.O.C. Custom Optical

My office has had a Briot edger for over 10 years
Dr. Albert Morier Consumer Optical

”Implementing the Briot® Attitude 2 has been effortless. It saves me time so I don’t need to spend extra hours in the office.“
Dr. Douglas King Owner, Family Eye Care Optometry Center

Dr. Paul Karpecki Kentucky Eye Institute
Dr. Paul Karpecki Kentucky Eye Institute

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.
Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.
“The VX65 refraction system is adaptable, quick to learn and easy to administer.”
Clark DeShon, OD, FAAO Practice Owner, Olney EyeCare

“I can safely and efficiently practice while also giving the patient confidence they are receiving top notch and modern care.”
Jordan Jones, O.D. Director of Eyecare, Wear Eyewear

Need help?
Get instant answers, explore our solutions, and find the right product in seconds.
Start chatting with Iris now and discover a smarter way to navigate Visionix!