Table With Eye refract, VX 22 and VX 40

Visionix VX 40

Complete prescription analysis in 30 seconds

Visionix Wavefront technology allows you to have a full detailed analysis of a frame at the push of the button. Experience the next generation auto lensmeter with the VX 40. The VX 40 can detect and analyze single vision, bifocals, and progressive lenses and is compatible with all lens technologies and brands.

Discover the main benefits of Visionix VX 40

Fully Automated

The VX 40 is fully automated. After the operator places the frame and initializes the start procedure, lens analysis and measurement are completely automatic. Even left / right eye movement requires no user input.

Easy to use

The unique lens holder system allows for fast insertion of the frame with only one hand! After pushing the start button, the whole process works on it’s own. The VX 40 allows you to spend more time with your patients and less time on analysis.

Automatic lens analysis

The VX 40 detects all types of lenses including bifocals, progressives, freeform, and single vision lenses. It is compatible with virtually every lens technology and brand.

Complete Visual Aanalysis

The VX 40 analyzes progressive and freeform lenses and then conveys the measurements to the operator in the form of a visual topographic map of the power ranges across the lens. These lens types no longer have to be a mystery to you.

Side By Side Progressive Lens Analysis

The lens is studied completely which allows for the operator to pick any point on the lens to verify the power and accuracy of the manufacturing. Compare and analyze even freeform progressive lens and show your patients the differences between different progressive lens designs.

Technical Specifications

Dimensions

  • WIDTH: 220 mm (8.66 in)
  • DEPTH: 240 mm (9.44 in)
  • HEIGHT: 455 mm (17.90 in)
  • WEIGHT: 9 kg (19.8 lbs)
  • VOLTAGE: 115 V – 230 V / 50 Hz – 60 Hz
  • STANDARDS: CE

Measurable range

  • Number of analyzed points: Up to 1350
  • Sphere power: -15 ~ +10D (step 0.01, 0.06, 0.125, 0.25D)
  • Cylinder power: 0~10D (step 0.01, 0.06, 0.125, 0.25D)
  • Cylinder axis: 0~180° (step 1°)
  • Addition power: 0~± 3.5D (step 0.01, 0.06, 0.125, 0.25D)
  • Prism power: 0~± 10 ∆ (step 0.01 ∆)
  • PD measurement: Mono / Bino
  • Cylinder: -, +

General

  • Printer: Internal
  • Screen: LCD/16M colours, 7’’
  • Light source: LED – 730 nm
  • Working conditions: 10 to 40°C
  • Data output: RS-232, Bluetooth

Testimonials

[Case Study MW 50D] Screening for Cataract

Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery

Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol

SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot

Download complete testimonial

Dr. Gray Sass, OD Wildwood Eyecare

Testimonials

[Case Study MW 50D] Screening for Cataract

Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Screening for refractive surgery

Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Retina protocol

SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Protocole Glaucome

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

Glaucoma protocol

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.

We are big fans of Briot

Download complete testimonial

Dr. Gray Sass, OD Wildwood Eyecare

Briot is my choice for lab equipment,

Download complete testimonial

Jonathan Kuckler, Vice President and Managing Optician North Colorado Optical of Greeley Inc.

I’m an old school optician

Download complete testimonial

Trish Hammons, A.B.O.C. Custom Optical

My office has had a Briot edger for over 10 years

Download complete testimonial

Dr. Albert Morier Consumer Optical

”Implementing the Briot® Attitude 2 has been effortless. It saves me time so I don’t need to spend extra hours in the office.“

Download complete testimonial

Dr. Douglas King Owner, Family Eye Care Optometry Center

Dr. Paul Karpecki Kentucky Eye Institute

Download complete testimonial

Dr. Paul Karpecki Kentucky Eye Institute

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.

Download complete testimonial

Dr. John Gelles is the director of the specialty contact lens division at The Cornea and Laser Eye Institute – Hersh Vision Group and The CLEI Center for Keratoconus.

“The VX65 refraction system is adaptable, quick to learn and easy to administer.”

Download complete testimonial

Clark DeShon, OD, FAAO Practice Owner, Olney EyeCare

“I can safely and efficiently practice while also giving the patient confidence they are receiving top notch and modern care.”

Download complete testimonial

Jordan Jones, O.D. Director of Eyecare, Wear Eyewear

Peter Remm -Kühl Optik

Mr Ganivet

Mr Notarianni

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Olivier Hesteau - Opticien de l'année 2015 - Krys Rennes

Chistophe Baudoin

Dr. Emily Enright

Dr. Jeff Gerson

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Paul Karpecki

Dr. Kambiz Silani

Dr. Kambiz Silani

Need more information?

Our teams are at your disposal to advise you