Next generation imaging from cornea to choroid.

OCT / OCT-A

OCT, or Optical Coherence Tomography, allows for fast and precise non-invasive visualization and quantification of the retina and optic nerve structure. By using light reflection, OCT provides detailed images of ocular tissue structure, enabling early detection of anomalies and monitoring of ocular disease progression. Therefore, OCT is an essential tool for diagnosing and effectively treating ocular health problems.

OCT Summary Screen

The Visionix OCT

Optical Coherence Tomography (OCT) is an advanced medical imaging technology that has revolutionized the way eye care professionals diagnose and manage a wide range of ocular conditions. Utilizing a non-invasive, high-resolution imaging system, OCT provides highly detailed, cross-sectional images of the retina, optic nerve, and anterior segment structures of the eye, allowing for earlier and more accurate detection of structural changes and disease progression. With the ability to detect subtle changes in tissue thickness and morphology, OCT has become an indispensable tool in the diagnosis and management of ocular diseases such as glaucoma, age-related macular degeneration, and diabetic retinopathy. By integrating OCT into their practices, eye care professionals can offer their patients the most advanced diagnostic and management options available, ultimately leading to improved patient outcomes and increased satisfaction.

Visionix - OCT

Early detection of ocular diseases

OCT enables early and accurate detection of structural changes in the eye, leading to more effective treatment and improved patient outcomes.

Detailed visualization of ocular structures

Optical Coherence Tomography  is non-invasive, making it safer and more comfortable for patients than other imaging methods.

Monitoring of the progression of ocular diseases.

OCT provides high-resolution images of ocular structures and quantification, giving healthcare professionals a detailed view of tissues and possible abnormalities.

Products

A patient being measured with the Optovue Solix SD-OCT

Optovue Solix SD-OCT

Optovue Solix is the next generation FullRange® OCT
and OCT-Angiography with a multitude of imaging
options, enhanced metrics, integrated fundus camera,
and external IR imaging. Optovue Solix is a new technology built upon a proven foundation of high-speed Spectral Domain OCT. With 120kHz scan speed, higher scan density, and better precision. This FullRange OCT delivers unparalleled data and efficiency.

  • Retina – FullRange Retina generates a 16×6.25mm scan enabling visualization of the vitreous and high myopes. The new high density 3D scans provide the images and data for comprehensive retinal analysis.
  • Glaucoma – DualTrac, SSADA, MCT, and AI segmentation components combined produce a 3D scan with 3x better R&R than previous systems for precise measurement of nerve fiber and change over time.
  • Anterior segment – FullRange Anterior scan 18×6.25mm to visualize and measure the entire Anterior chamber or crystalline lens , combined with pachymetry and angle measurements.
Vue de profil du Optovue Solix Essential OCT

Optovue Solix Essential SD-OCT

Optovue Solix Essential is a technology built upon a proven foundation of high-speed Spectral Domain OCT. The Optovue Solix Essential offers state-of-the-art imaging from the cornea to the choroid with exclusive technology that will change your approach to disease diagnosis and management.

  • Retina – The new high density 3D scans provide the images and data for comprehensive retinal analysis.
  • Glaucoma – DualTrac, SSADA, MCT, and AI segmentation components combined produce a 3D scan with 3x better R&R than previous systems for precise measurement of nerve fiber and change over time.
  • Anterior segment – Corneal scans including pachymetry, angle measurements and 3D.

Optovue iScan 80

iScan 80 offers a fully-integrated system which includes a full suite of retina, optic nerve and anterior segment scans. It detects the eye to be scanned, aligns the camera over the pupil and optimises the scan signal strength. After completing scan acquisition, iScan 80 evaluates each scan to ensure quality data has been captured.
  • Simplified operation – iScan 80 OCT offers all neccessary scans, easy acquisition with Pupil Alignment Technology.
  • Space-saving design – Streamlined design integrates all components into one portable console.
  • iWellness Exam – iWellnessExam provides comprehensive OCT scan for better patient eye health.
iVue 80 OCT avec option rétinographe

Optovue iVue 80

The iVue 80 OCT is a powerful clinical tool that transforms the way you assess the retina, optic disc and the cornea. Quantify the thickness of the retina, nerve fiber layer, ganglion cell complex and the cornea. Track change and predict trends in RNFL and GCC thickness and precisely measure angles to aid in disease diagnosis.
  • 80,000 A-Scans Per Second – 3x faster than the original iVue OCT, improved efficiency and enhanced image quality
  • Simplified Scan Acquisition – Real-time en-face imaging displays 12x9mm retina view during acquisition.
  • Easy-To-Use Platform – Easy-to-use iVue 80 has familiar operation and is quickly mastered by new technicians.

Optovue iFusion 80

The iFusion 80 OCT and retinal imaging system has all the same powerful clinical tools as the Ivue with the added benefit of the iCam 12 retinal camera. The iFusion80 transforms the way you assess the retina, optic disc and the cornea. Quantify the thickness of the retina, nerve fiber layer, ganglion cell complex (GCC) and the cornea. Track changes and predict trends in RNFL and GCC thickness and precisely measure angles to aid in disease diagnosis.
  • Color Photography – 12Mp imaging of the Fundus, Disc and Exterior orbit
  • iWellnessExam – iWellnessExam provides comprehensive OCT scan for better patient eye health.
  • Retinal mapping and analysis – Easy to read retina reports with change analysis, RDB and color photo overlays.

Model Comparison

Solix

Solix Essential

iFusion 80

iScan 80

iVue 80

Technology

Transverse resolution(15μm) ✔️ ✔️ ✔️ ✔️ ✔️
Scan speed 120kHz 120kHz 80kHz 80kHz 80kHz
Axial resolution(5μm) ✔️ ✔️ ✔️ ✔️ ✔️
iWellness scan ✔️ ✔️ ✔️ ✔️ ✔️
AngioVue single scan for structural & vascular OCT ✔️ ✔️
AngioVue OCT-A with enhanced metrics ✔️ ✔️
Multi-volume averaging, SSADA ✔️ ✔️
3D PAR 2.0 ✔️ ✔️
DualTrac – Motion Correction Technology (MCT) ✔️ ✔️
Pixel x pixel deviation mapping ✔️ ✔️
AngioWellness scan ✔️ ✔️
Fully automated with voice-guided technology ✔️

Anterior segment

Anterior radial (12mm) ✔️ ✔️ ✔️ ✔️ ✔️
Angle scan ✔️ ✔️ ✔️ ✔️ ✔️
Epithelial, stromal, and corneal thickness mapping ✔️ ✔️ ✔️ ✔️ ✔️
Pachymetry 10mm 10mm 6mm 6mm 6mm
Angle scan and analysis with 4-up display ✔️ ✔️ ✔️ ✔️ ✔️
External color camera ✔️ ✔️
FullRange anterior segment 18 x 6.25mm ✔️
Exterior IR lid imaging ✔️
Pachymetry, epithelial thickness, and stroma trend analysis ✔️ ✔️
FullRange anterior chamber auto caliper placement ✔️
Side-by-side pachymetry, epithelial thickness, and stroma maps ✔️ ✔️

Glaucoma

3D disc cube ✔️ ✔️ ✔️ ✔️ ✔️
GCC analysis ✔️ ✔️ ✔️ ✔️ ✔️
Nerve fiber layer analysis ✔️ ✔️ ✔️ ✔️ ✔️
Comprehensive single-eye and OU reports ✔️ ✔️ ✔️ ✔️ ✔️
RPC density map and values ✔️ ✔️
100 μm RNFL circle at 3.45mm ✔️ ✔️
3 times repeatability and reproducibility (R&R) ✔️ ✔️

Retina

EnFace 12 x 12 mm 12 x 12mm 12 x 9mm 12 x 9mm 12 x 9mm
3D retina cube ✔️ ✔️ ✔️ ✔️ ✔️
Radial line ✔️ ✔️ ✔️ ✔️ ✔️
512 OCT-A scans ✔️ ✔️
3D vessel rendering ✔️ ✔️
AngioVue QuadMontage ✔️ ✔️
Retinal thickness map (Widefield OCT-A 12 x 12mm, 9 x 9mm) ✔️ ✔️
Fundus camera ✔️ ✔️
FullRange retinal scan 16 x 6.25mm ✔️

Topography (optional feature)

Topography (Anterior and posterior corneal + tomography) ✔️ ✔️
Zenike values with high order and low order aberrations ✔️ ✔️
Total net power ✔️ ✔️

Need more information?

Our teams are at your disposal to advise you

Why use an OCT?

What is Epithelial Thickness Mapping for?

Quantify epithelial, stromal and total corneal thickness with the 10mm Corneal Layer Map, which features 16 meridians to fully cover the LRS transition zone. Use the Highlight Tool to further appreciate subtle changes in thickness. The Change Analysis report measures changes in thickness between visits.

What are the benefits of OCT technology for glaucoma screening and monitoring?

The Solix Nerve fiber package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-new high density scans bring additional insights that aid in clinical decision making. A single scan with Motion Correction Technology (MCT) generates both OCT and OCTA images with AngioAnalytics metrics to optimize efficiency and help you quickly understand each patient’s rate of change.

What is OCT iWellness protocol?

OCT Wellness generates a comprehensive OU report to promote better overall eye health. The report includes a 12x9mm structural scan that optimizes metrics on retinal and ganglion cell thickness. High-resolution B-scans provide excellent visualization of retinal structures.