The Visionix range of examination slit lamps offer superior optical quality and exceptional durability. With advanced optics, various magnification options, and robust construction, Visionix slit lamps provide high-resolution images for accurate diagnosis and effective monitoring of ocular conditions
Visionix slit lamps offer a wide range of magnification options, allowing for detailed observation of the eye’s structure. Built-in optical filters can be used to enhance visibility of eye structures and diagnose conditions such as cataracts, glaucoma, diabetic retinopathy, eye tumors, and corneal abnormalities. Visionix slit lamps are designed with durability in mind, using materials that are resistant to wear and tear and impact.
The versatility of our slit lamps make them an essential tool for eye care professionals, enabling them to examine the eye at various levels of detail and diagnose a wide range of eye conditions.
Integrated digital imaging system, allowing the eye care professional to capture high-resolution images of the eye for documentation and analysis. Essential for monitoring conditions over time or sharing images with other healthcare professionals
Designed with great durability using materials resistant to wear and impact, these instruments also feature an ergonomic design for the comfort of the eye care professional and the patient.
New high performance digital LED slit lamp, with wide magnification range and fine optics.
New high performance LED slit lamp, with wide magnification range and fine optics.
MW 50D Digital |
MW 50D Clinical |
||
Magnifications | 5x/10x/16x/25x/50x | 5x/10x/16x/25x/50x | |
Parallel version | |||
Convergent version | ✔️ | ✔️ | |
Height adjustment:
manual version
|
✔️ | ✔️ | |
Height adjustment:
motorized version
|
|||
Slit width | 0 – 16 mm Continually | 0 – 16 mm Continually | |
Slit length | 1 – 16 mm Continually | 1 – 16 mm Continually | |
Slit apertures | 16; 14; 10; 5; 2; 1; 0,2mm | 16; 14; 10; 5; 2; 1; 0,2mm | |
Tyndall point | Ø 0,2mm | Ø 0,2mm | |
Slit rotation | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme | |
Working distance | 100.5mm | 100.5mm | |
Average viewing height | 374mm | 374mm | |
Light | LED | LED | |
Max light intensity | 300 000 Lux | 300 000 Lux | |
Longitudinal (In/Out) |
100mm | 100mm | |
Lateral (Left/Right) |
110mm | 110mm | |
Vertical (Up/Down) |
30mm | 30mm | |
Chin-rest height |
76mm from table surface | 76mm from table surface | |
Stereo angle |
8° | 8° | |
Eyepiece | 12,5x | 12,5x | |
Total magnification/field of view (in mm) for 2 magnifications |
|||
Total magnification/field of view (in mm) for 3 magnifications |
|||
Total magnification/field of view (in mm) for 5 magnifications |
5x/44.5; 10x/22,3;
16x/14,2; 25x/9 ; 50x/4,5
|
5x/44.5; 10x/22,3;
16x/14,2; 25x/9 ; 50x/4,5
|
|
Pupillary adjustement | 55 – 80mm | 55 – 80mm | |
Diopter ajustment | +/- 8D | +/- 8D | |
Blue (fluorescence) | ✔️ | ✔️ | |
Green (red-free) | ✔️ | ✔️ | |
Grey (anti heat) | ND (12.5%) | ND (12.5%) | |
Yellow | ✔️ | ✔️ | |
Power supply | Provided | Provided | |
Power supply for the slit lamp | DC12V | DC12V | |
Power supply for the fixation point | DC12V | DC12V | |
Input voltage |
100V – 240V AC;
60/50Hz
|
100V – 240V AC;
60/50Hz
|
|
Fusible | T400mmAH 250V | T400mmAH 250V | |
Width | 350mm | 350mm | |
Depth | 387mm | 387mm | |
Height | 678.5mm | 678.5mm | |
Weight | Packed: 22Kg | Packed: 22Kg | |
MDD, CE | ✔️ | ✔️ | |
---|---|---|---|
Safety class | I | I | |
Parts applied | Type B | Type B | |
Tonometer | 8475-8000-00 | 8475-8000-00 | |
Tonometer support plate | 8226-8400-04 | 8226-8400-04 |