Plate-forme multimodale, combinant ARK et topographe Placido.
Le VX 110 est une plateforme multimodale qui associe un autoréfractomètre kératomètre à un topographe Placido. Le VX 110 offre de multiples fonctionnalités tout en étant pratique et peu encombrant. Instrument de haute précision et haute résolution, le VX 110 va vraiment au-delà de la simple réfraction. Il permet aux professionnels de la santé visuelle de proposer des examens plus simples et plus complets, pour l’opérateur comme pour le client.


| Feature | Value |
|---|---|
| AR-K | • |
| Occular Aberro. | • |
| Retro | • |
| Corneal Topograph | • |
| Non Contact Tonometer |

| Feature | Value |
|---|---|
| Pachymetry | |
| Full Eye Tracking | • |
| Back surface of the cornea | |
| Remote Acces | • |
| Offline/Webservice | • |
| Colour camera |

| Feature | Value |
|---|---|
| NBUT | |
| Efron classification | |
| Tear meniscus value |

| Feature | Value |
|---|---|
| Alignment | XYZ automatic |
| Display | 10.1” (1 024 x 600) TFT multi-touch screen |
| Observation area | ø 14 mm |
| Medical device directive | EC MDD 93/42/EC modified by directive 2007/47/EC |
| Output | RS232 / USB / VGA / LAN |

| Feature | Value |
|---|---|
| Spherical power range | -20D to +20D |
| Cylinder power range | 0D to + 8D |
| Axis | 0 to 180° |
| Measuring area | Min. ø 2 mm – Max. 7 mm (3 zones) |
| Number of measuring points | 1,300 points |
| Acquisition time | 0.2 sec |
| Method | Shack-Hartmann |

| Feature | Value |
|---|---|
| Method | Continuous horizontal scan with the Scheimpflug camera |
| Pachymeter measuring range | 150-1300 μm |
| Pachymeter resolution | +/- 10 microns |
| IC angle measuring range | 0°-60° |
| IC resolution | 0.1° |
| Pupil illumination | Blue light 455 nm |

| Feature | Value |
|---|---|
| Number of rings | 24 |
| Number of measuring points | 6.144 |
| Number of points analyzed | More than 100,000 |
| Diameter of covered corneal area at 43D | From 0.75 mm to more than 10 mm |
| Measurement range | From 37.5 D to 56 D |
| Repeatability | 0.02 D |
| Method | Placido rings |

| Feature | Value |
|---|---|
| Measurement range | 7 mmHg to 44 mmHg |
| VX 110 | VX 120+ | VX 120+ Dry Eye | VX 130+ | VX 650 | |
|---|---|---|---|---|---|
| AR-K based WF. | |||||
| AR-K | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Occular Aberro. | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Retro | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Corneal Topograph | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Non Contact Tonometer | ✔️ | ✔️ | ✔️ | ✔️ | |
| Scheimpflug Camera | ✔️ | ✔️ | ✔️ | ✔️ | |
| Pachymetry | ✔️ | ✔️ | ✔️ | ✔️ | |
| Full Eye Tracking | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Back surface of the cornea | ✔️ | ✔️ | |||
| Remote Access | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Colour camera | ✔️ | ✔️ | |||
| Dry eye | ✔️ | ✔️ | |||
| NBUT | ✔️ | ✔️ | |||
| Efron classification | ✔️ | ✔️ | |||
| Tear meniscus value | ✔️ | ✔️ | |||
| Fundus Camera | ✔️ |

Il a été facile d'intégrer la Briot Attitude 2 dans mon activité. Elle me fait gagner du temps, ce qui m'évite de faire des heures supplémentaires au bureau.
Dr. Douglas King Owner, Family Eye Care Optometry Center
Nos équipes sont à votre disposition pour vous conseiller.