Lámpara de hendidura de examen VX 70
El moderno diseño y el sistema de revestimiento múltiple de la Visionix VX 70 transmite la luz de forma más eficiente y satisfará todas las necesidades de la lámpara de hendidura de su consulta.
La luz LED utiliza menos energía y puede durar más de cien veces que una fuente halógena. El LED también proporciona una mejor iluminación uniforme que aumenta la calidad de la imagen.

| Feature | Value |
|---|---|
| Magnifications | 2x/3x/5x |
| Convergent version | • |
| Height adjustment: | • |
| Slit width | 0 – 14 mm Continually |
| Slit length | 0 – 14 mm Continually |
| Slit apertures | 14; 10; 6; 4; 3; 1; 0,2mm |
| Tyndall point | Ø 0,2mm |
| Slit rotation | ± 90° Continually on TABO scheme |
| Working distance | 100mm |
| Average viewing height | 375mm |
| Light | LED |
| Max light intensity | 300 000 Lux |
| Longitudinal (In/Out) | 99mm |
| Lateral (Left/Right) | 118mm |
| Vertical (Up/Down) | 30mm |
| Chin-rest height | 76mm |
| Stereo angle | 6° |
| Eyepiece | 10x |
| Total magnification/field of view (in mm) for 2 magnifications | 10x/27; 16x/16 |
| Total magnification/field of view (in mm) for 3 magnifications | 10x/27; 16x/16; 25x/11 |
| Total magnification/field of view (in mm) for 5 magnifications | 6x/43; 10x/27; 16x/16; 24x/11; 40x/7 |
| Pupillary adjustement | 52 – 90mm (2 magnifications) 55 – 75mm (3 or 5 magnifications) |
| Diopter ajustment | +/- 6D |
| Blue (fluorescence) | • |
| Green (red-free) | • |
| Grey (anti heat) | • |
| Power supply | Provided |
| Power supply for the slit lamp | 3,4V, 700mA |
| Power supply for the fixation point | 5v |
| Input voltage | 110V / 220V AC; 60/50Hz |
| Fusible | NA |
| Width | 380mm |
| Depth | 530mm |
| Height | 780mm |
| Weight | Packed: 26Kg (2 magnifications), 28Kg (3 or 5 magnifications) |
| MDD, CE | • |
| Safety class | I |
| Parts applied | Type B |
| Tonometer | 8480-5010-00 |
| Tonometer support plate | Provided with the tonometer |
| VX 70 | VX 75 | VX 80 | VX 85 | |
|---|---|---|---|---|
| Magnifications | 2x/3x/5x | 3x/5x | 3x/5x | 3x/5x |
| Convergent version | ✔️ | ✔️ | ✔️ | ✔️ |
| Height adjustment: | ✔️ | ✔️ | ✔️ | ✔️ |
| Height adjustment motorized version: | ✔️ | |||
| Slit width | 0 - 14 mm Continually | 0 - 14 mm Continually | 0 - 14 mm Continually | 0 - 12mm Continually |
| Slit length | 0 - 14 mm Continually | 1,8 - 13mm Continually | 1 - 12mm Continually | 1,5 - 11mm Continually |
| Slit apertures | 14; 10; 6; 4; 3; 1; 0,2mm | 14; 9; 5,5; 0,3mm | 12; 9; 5; 3; 1; 0,2mm | 12; 8; 5; 0,2mm |
| Tyndall point | Ø 0,2mm | Ø 0,3mm | Ø 0,2mm | Ø 0,2mm |
| Slit rotation | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme |
| Working distance | 100mm | 68mm | 88mm | 68 mm |
| Average viewing height | 375mm | 375mm | 375mm | 375mm |
| Light | LED | LED | LED | LED |
| Max light intensity | 300 000 Lux | 350 000 Lux | 350 000 Lux | 350 000 Lux |
| Longitudinal (In/Out) | 99mm | 113mm | 113 mm | 113 mm |
| Lateral (Left/Right) | 118mm | 107 mm | 107 mm | 100mm |
| Vertical (Up/Down) | 30mm | 30 mm | 30 mm | 30mm |
| Chin-rest height | 76mm | 76 ±1mm | 66 ±1mm | 70mm |
| Stereo angle | 6° | 6° | 6° | 6° |
| Eyepiece | 10x | 12,5x | 12,5x | 12,5x |
| Total magnification/field of view (in mm) for 2 magnifications | 10x/27; 16x/16 | |||
| Total magnification/field of view (in mm) for 3 magnifications | 10x/27; 16x/16; 25x/11 | 8x /30 ; 14x /16 ; 24x / 9 | 8x /30 ; 14x /16 ; 24x / 9 | NA |
| Total magnification/field of view (in mm) for 5 magnifications | 6x/43; 10x/27; 16x/16; 24x/11; 40x/7 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 |
| Pupillary adjustement | 52 - 90mm (2 magnifications) 55 - 75mm (3 or 5 magnifications) | 48,5 - 80mm | 48,5 - 80mm | 48,5 - 80mm |
| Diopter ajustment | +/- 6D | +/- 6D | +/- 6D | +/- 6D |
| Blue (fluorescence) | ✔️ | ✔️ | ✔️ | ✔️ |
| Green (red-free) | ✔️ | ✔️ | ✔️ | ✔️ |
| Grey (anti heat) | ✔️ | ✔️ | ✔️ | ✔️ |
| Yellow | ✔️ | ✔️ | ✔️ | |
| Power supply | Provided | 8475-8001-00 | 8475-8001-00 | 8485-8001-00 |
| Power supply for the slit lamp | 3,4V, 700mA | ~12V AC | ~12V CA; | 12V AC |
| Power supply for the fixation point | 5v | 12V | 12V | 12V |
| Input voltage | 110V / 220V AC; 60/50Hz | 100V/120V/230V/240V AC; 60/50Hz | 110V / 220V AC; 60/50Hz | 110V / 220V AC; 60/50Hz |
| Fusible | NA | 100-120V CA -- 1A 230-240V CA -- 0,5A | 100-120V CA -- 1A 230-240V CA -- 0,5A | 1,2A |
| Width | 380mm | 296mm | 299mm | 240mm |
| Depth | 530mm | 313mm | 313mm | 300mm |
| Height | 780mm | 433±15mm | 644±15mm | 440mm |
| Weight | Packed: 26Kg (2 magnifications), 28Kg (3 or 5 magnifications) | Lamp: 7,4Kg Digital lamp: 8,1Kg | Lamp: 8,7Kg Digital lamp: 9,4Kg | 12,0Kg Instrument (excluding accessories; Headrest: 1,5Kg) |
| CE : MDR - (EU) 2017/745 | ✔️ | ✔️ | ✔️ | ✔️ |
| Safety class | I | I | I | I |
| Parts applied | Type B | Type B | Type B | Type B |
| Tonometer | 8480-5010-00 | 8475-8000-00 | 8480-8000-00 | 8475-8000-00 |
| Tonometer support plate | Provided with the tonometer | 8475-8002-00 | 8480-8003-00 | 8475-8002-00 |
| Compatibility with EyePix3 | ✔️ | ✔️ | ✔️ |
[Caso clínico MW 50D] Screening de catarata
Cataract is a medical condition in which the lens of the eye becomes progressively opaque (1A), resulting in blurred vision. According to the World Health Organization, cataract is the leading cause of blindness in the world.

Evaluación para cirugía refractiva
Raise awareness on the importance of Epithelial Thickness Mapping (ETM) in refractive surgery screening.

Protocolo de Retina
SOLIX delivers pristine images of retinal structures with unprecedented views of the vitreous and choroid, that enable confident diagnosis and management of retinal pathologies.

Protocolo Glaucoma
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature. Optovue-exclusive scans bring additional insights that aid in clinical decision making.
Somos grandes seguidores de Briot
Dr. Gray Sass, OD Wildwood Eyecare

Dr. Gray Sass, OD Wildwood Eyecare

Implementar el Briot® Attitude 2 no ha supuesto ningún esfuerzo. Me ahorra tiempo y no necesito alargar mis horas de trabajo
Dr. Douglas King Owner, Family Eye Care Optometry Center

Mi óptica tiene una biseladora Briot desde hace más de 10 años
Dr. Albert Morier Consumer Optical
Soy un óptico tradicional
Trish Hammons, A.B.O.C. Custom Optical