Lámpara de hendidura de examen VX 70
El moderno diseño y el sistema de revestimiento múltiple de la Visionix VX 70 transmite la luz de forma más eficiente y satisfará todas las necesidades de la lámpara de hendidura de su consulta.
La luz LED utiliza menos energía y puede durar más de cien veces que una fuente halógena. El LED también proporciona una mejor iluminación uniforme que aumenta la calidad de la imagen.
Feature | Value |
---|---|
Magnifications | 2x/3x/5x |
Convergent version | • |
Height adjustment: | • |
Slit width | 0 – 14 mm Continually |
Slit length | 0 – 14 mm Continually |
Slit apertures | 14; 10; 6; 4; 3; 1; 0,2mm |
Tyndall point | Ø 0,2mm |
Slit rotation | ± 90° Continually on TABO scheme |
Working distance | 100mm |
Average viewing height | 375mm |
Light | LED |
Max light intensity | 300 000 Lux |
Longitudinal (In/Out) | 99mm |
Lateral (Left/Right) | 118mm |
Vertical (Up/Down) | 30mm |
Chin-rest height | 76mm |
Stereo angle | 6° |
Eyepiece | 10x |
Total magnification/field of view (in mm) for 2 magnifications | 10x/27; 16x/16 |
Total magnification/field of view (in mm) for 3 magnifications | 10x/27; 16x/16; 25x/11 |
Total magnification/field of view (in mm) for 5 magnifications | 6x/43; 10x/27; 16x/16; 24x/11; 40x/7 |
Pupillary adjustement | 52 – 90mm (2 magnifications) 55 – 75mm (3 or 5 magnifications) |
Diopter ajustment | +/- 6D |
Blue (fluorescence) | • |
Green (red-free) | • |
Grey (anti heat) | • |
Power supply | Provided |
Power supply for the slit lamp | 3,4V, 700mA |
Power supply for the fixation point | 5v |
Input voltage | 110V / 220V AC; 60/50Hz |
Fusible | NA |
Width | 380mm |
Depth | 530mm |
Height | 780mm |
Weight | Packed: 26Kg (2 magnifications), 28Kg (3 or 5 magnifications) |
MDD, CE | • |
Safety class | I |
Parts applied | Type B |
Tonometer | 8480-5010-00 |
Tonometer support plate | Provided with the tonometer |
VX 70 | VX 75 | VX 80 | VX 85 | |
---|---|---|---|---|
Magnifications | 2x/3x/5x | 3x/5x | 3x/5x | 3x/5x |
Convergent version | ✔️ | ✔️ | ✔️ | ✔️ |
Height adjustment: | ✔️ | ✔️ | ✔️ | ✔️ |
Height adjustment motorized version: | ✔️ | |||
Slit width | 0 - 14 mm Continually | 0 - 14 mm Continually | 0 - 14 mm Continually | 0 - 12mm Continually |
Slit length | 0 - 14 mm Continually | 1,8 - 13mm Continually | 1 - 12mm Continually | 1,5 - 11mm Continually |
Slit apertures | 14; 10; 6; 4; 3; 1; 0,2mm | 14; 9; 5,5; 0,3mm | 12; 9; 5; 3; 1; 0,2mm | 12; 8; 5; 0,2mm |
Tyndall point | Ø 0,2mm | Ø 0,3mm | Ø 0,2mm | Ø 0,2mm |
Slit rotation | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme | ± 90° Continually on TABO scheme |
Working distance | 100mm | 68mm | 88mm | 68 mm |
Average viewing height | 375mm | 375mm | 375mm | 375mm |
Light | LED | LED | LED | LED |
Max light intensity | 300 000 Lux | 350 000 Lux | 350 000 Lux | 350 000 Lux |
Longitudinal (In/Out) | 99mm | 113mm | 113 mm | 113 mm |
Lateral (Left/Right) | 118mm | 107 mm | 107 mm | 100mm |
Vertical (Up/Down) | 30mm | 30 mm | 30 mm | 30mm |
Chin-rest height | 76mm | 76 ±1mm | 66 ±1mm | 70mm |
Stereo angle | 6° | 6° | 6° | 6° |
Eyepiece | 10x | 12,5x | 12,5x | 12,5x |
Total magnification/field of view (in mm) for 2 magnifications | 10x/27; 16x/16 | |||
Total magnification/field of view (in mm) for 3 magnifications | 10x/27; 16x/16; 25x/11 | 8x /30 ; 14x /16 ; 24x / 9 | 8x /30 ; 14x /16 ; 24x / 9 | NA |
Total magnification/field of view (in mm) for 5 magnifications | 6x/43; 10x/27; 16x/16; 24x/11; 40x/7 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 | 5x/45; 8x/30; 14x/16; 24x /9; 36x / 5, 8 |
Pupillary adjustement | 52 - 90mm (2 magnifications) 55 - 75mm (3 or 5 magnifications) | 48,5 - 80mm | 48,5 - 80mm | 48,5 - 80mm |
Diopter ajustment | +/- 6D | +/- 6D | +/- 6D | +/- 6D |
Blue (fluorescence) | ✔️ | ✔️ | ✔️ | ✔️ |
Green (red-free) | ✔️ | ✔️ | ✔️ | ✔️ |
Grey (anti heat) | ✔️ | ✔️ | ✔️ | ✔️ |
Yellow | ✔️ | ✔️ | ✔️ | |
Power supply | Provided | 8475-8001-00 | 8475-8001-00 | 8485-8001-00 |
Power supply for the slit lamp | 3,4V, 700mA | ~12V AC | ~12V CA; | 12V AC |
Power supply for the fixation point | 5v | 12V | 12V | 12V |
Input voltage | 110V / 220V AC; 60/50Hz | 100V/120V/230V/240V AC; 60/50Hz | 110V / 220V AC; 60/50Hz | 110V / 220V AC; 60/50Hz |
Fusible | NA | 100-120V CA -- 1A 230-240V CA -- 0,5A | 100-120V CA -- 1A 230-240V CA -- 0,5A | 1,2A |
Width | 380mm | 296mm | 299mm | 240mm |
Depth | 530mm | 313mm | 313mm | 300mm |
Height | 780mm | 433±15mm | 644±15mm | 440mm |
Weight | Packed: 26Kg (2 magnifications), 28Kg (3 or 5 magnifications) | Lamp: 7,4Kg Digital lamp: 8,1Kg | Lamp: 8,7Kg Digital lamp: 9,4Kg | 12,0Kg Instrument (excluding accessories; Headrest: 1,5Kg) |
CE : MDR - (EU) 2017/745 | ✔️ | ✔️ | ✔️ | ✔️ |
Safety class | I | I | I | I |
Parts applied | Type B | Type B | Type B | Type B |
Tonometer | 8480-5010-00 | 8475-8000-00 | 8480-8000-00 | 8475-8000-00 |
Tonometer support plate | Provided with the tonometer | 8475-8002-00 | 8480-8003-00 | 8475-8002-00 |
Compatibility with EyePix3 | ✔️ | ✔️ | ✔️ |